970CRT® Double Beam Spectrofluorophotometer
970CRT® Double Beam Spectrofluorophotometer is the high leve1 spectrofIuorophotometer in our country. The current advanced computer software and hardware of PC are adopted in this instrument. It has the best property of qualitative and quantitative testing, and is widely used for micro and trace analysis and test in the case of chemica1 experiment, medicinal inspection, environmental protection, petroleum industry, chemical industry, medical hygiene, foodstuff nutrition and so on. |
|
|
High sensitivity, high Signal/noise ratio, S/N can reach over 100. |
 |
The technology of light source monitoring is adopted. The test resu1t is stable. |
 |
It uses the rapid 20 digits A/D transformation technology. The dynamic measuring range is wide, and the linearity is better. |
 |
The function of data atlas processing is powerful and the operation is easy and convenient. |
 |
Use the Standard PC computer as the hardware circumstance. The failure rate of instrument is low and the reliability is better. |
 |
Windows with English dialogue is used entirely in the station. It can control the main machine directly and proceed with the data processing. |
 |
A series of operation of scan testing, data analyzing, table making and recording can be easily completed by pressing the mouse button. |
 |
The 20 bits high speed A/D transformer is used. The dynamical range is large. The mini changes of sample can be tested rapidly and exactly. |
 |
| Function of software: |
| (1) |
Filtering: 1~4 orders of derivative, peak retrieving, peak area calculating, continuous scan testing, quantitative sample analyzing, plotting the standard curve (1~3 times), finding the concentration of test sample according to the standard curve, at1as saving and loading, atlas window treating, automatic testing the ratio of S/N and so on. |
| (2) |
Database function. |
|
|
|
Light source: 150W xenon lamp |
 |
Measuring range of wavelength: Exciting 200-800nm; fluorescence 200-800nm |
 |
Slit: Exciting 2, 5, 10, 20nm, 4 grades; fluorescence 2, 5, 10, 20, 30, 40nm, 6 grades |
 |
Wavelength precision: ¡À2nm |
 |
Wavelength repeatability: ¡À0.5nm |
 |
Scanning speed: Extra fast; fast midd1e; slow |
 |
Time scanning: 60, 300, 600, 900, 1200, 1800 sec, 6 grades |
 |
Sensitivity: 8 grades turn-over for selection |
|
Response speed: Lame peak of distilled water 0~98% about 2sec |
 |
Signal/noise (S/N ratio): When the bandwidth of exciting and f1uoro 1ight is i0 nm, lame peak S/N ratio of distilled water is larger than 100. |
 |
Zero modulation: Automatically or manually |
 |
Dimension: 620¡Á576¡Á270mm |